This year has been a milestone for Imatest. We’ve introduced an array of innovative products, software, and services, thanks to the unwavering support of our customers. We’re immensely grateful for this collaboration and eagerly anticipate bringing even more advancements in the coming year.
Imatest Benchtop Test Stand
New Slanted Edge Based Measurements
- Information Capacity
- Ideal Observer Signal-to-Noise Ratio (SNRi)
- Noise Power Spectrum (NPS)
- Noise Equivalent Quanta (NEQ)
Stray Light
- Added ability to normalize by a user-provided value.
- Added ability to have separate masking settings for the reference image.
- Output pixel count above a threshold.
- Switches to median aggregation in reference image normalization.
- Added ability to directly use the image processing mask method.
- Added ability to set the threshold in image processing masking via Otsu’s method.
- Added a minimum source threshold to the image processing method.
- Added other compensation factors for normalization via a reference image.
- Larger summary plots, updates to nomenclature.
Improved Settings & GUI Updates
- Improved Settings
- Imatest Database
- Image Preview Improvements
Arbitrary Charts
- Auto Exposure measurement compliant with VCX Webcam 2023
- Distortion parameter
Flatfield/EMVA 1288
- Adds calculations for row, column, and pixel noise spatial variances to Flatfield interactive and fixed modules based on EMVA 1288 Version 4.0 Linear
Improved SFRreg Detection
Tour Mode
eSFR ISO 12233 2023 “Slanted Star”
- double the slanted-edge measurement regions.
- Logarithmic wedges with improved frequency distribution.
- 18 color patches similar to the industry standard 24-patch chart.
- New test chart available: Inkjet, Lightboxes, High-precision Film.
Additional linearization options for eSFR ISO & SFRplus
Dynamic Range Postprocessor
- Produces results similar to IEEE P2020 (draft) noise standard. Described in A review of IEEE P2020 noise metrics
- Now supports sensor dynamic range calculations from multi-image exposures from HDR sensors.
MacOS 14 Sonoma Support
Main Window Improvements
Stray Light
- Supports the IEEE-P2020 pre-release flare attenuation calculation. Our next-generation light source, scheduled for late 2023/early 2024, will meet the uniformity requirements for accurate calculation of flare attenuation. Imatest recommends P2020 (draft) normalized stray light calculation with our current Stray Light LED Light Source.
- Ability to normalize with a reference image of a Lambertian diffuser.
- Ability to choose output data transforms including linear, logarithmic, and decibel.
- Ability to subtract off a dark level.
- Ability to have level count summary metrics expressed as a percentage.
- Ability to select an analysis channel including: RGB, Each Channel, Mean, and Luminance.
- Improved visualization of masked pixels in colormapped metric images.
- Now includes the minimum measurable stray light in results.
- Customized service that achieves the testing objectives of your organization while working within your budget.
- Trained consultants will spend time with your team to better understand your needs and create a test plan to meet your project goals.
- Our detail-oriented engineers will test your equipment using our hardware, charts, and software to analyze images and interpret results—saving you time and resources.
- Provide consistent, repeatable, and trustworthy results through rigorous testing protocols, allowing you to build a portfolio of reports.
Service Offerings:
- Sensor evaluation
- Camera hardware design
- ISP tuning
- Benchmarking