Slanted-Edge versus Siemens Star, Part 2

A comparison of sensitivity to signal processing: Results for additional cameras This page contains additional Slanted-edge, Siemens Star, and Log F-Contrast results for four cameras, in support of claims in Slanted-edge versus Siemens Star that Siemens Star MTF measurements are nearly as sensitive to sharpening as low-contrast (4:1) slanted-edge measurements. The Siemens Star’s high contrast (specified at >50:1) makes it quite sensitive to saturation and to “shoulders” (regions of reduced contrast) in camera tonal response. Slanted-edge MTF measurements are stable, reliable, and more representative of perceived image sharpness under a wide range of conditions (in addition to their many well-known […]

Slanted-Edge versus Siemens Star

A comparison of sensitivity to signal processing In this page we address concerns about the sensitivity of slanted-edge patterns to signal processing, especially sharpening, and we correct the misconception that sinusoidal patterns, such as the Siemens star, are insensitive to sharpening, and hence provide more robust and stable MTF measurements. The Siemens Star is of particular interest because, along with the slanted-edge, it is included in the ISO 12233:2014 standard.  To summarize our results, we found that sinusoidal patterns are sensitive to sharpening, though often less so than low contrast (4:1) slanted-edges. The relatively high contrast of the Siemens Star […]

Skype video specification support

Instructions and comments We are updating this page for the latest Skype/Lync specification. An index of of the Skype/Lync specifications can be found on  http://technet.microsoft.com/en-us/lync/gg278181.aspx. This document contains instructions for using Imatest with the Skype Hardware Certification Specification — For all Skype Video Devices Version 5.0. It also contains comments and suggestions (some of which we hope might be adopted in a future release of the spec). The Skype spec uses only a tiny fraction of Imatest’s powerful capabilities. To learn more, see Image Quality Factors and SFRplus (which allows many factors to be measured from a single image). In […]

Skype for Business Video Specification Support

Instructions and comments Under development We are updating this page for the latest Skype for Business Video Capture Specification, December 2016. An index of of the Skype/Lync specifications can be found on https://technet.microsoft.com/en-us/office/dn788953 This document contains instructions for using Imatest with the Skype for Business Video Capture Specification, which has two versions: personal solutions (Document Number: H100693) and conferencing devices (Document Number: M1023160), published December 2016. “Skype for Business V3.0” appears on a watermark, and 3.0 is indicated in the Revision History (Section 1). It also contains comments and suggestions for running Imatest. The Skype spec uses only a tiny […]

Sharpening

Introduction – Examples – Oversharpening and Undersharpening  Examples – Unsharp masking (USM) – Links   Introduction to sharpening Sharpening is an important part of digital image processing. It restores some of the sharpness lost in the lens and image sensor. Every digital image benefits from sharpening at some point in its workflow— in the camera, the RAW conversion software, and/or image editor. Sharpening has a bad name with some photographers because it’s overdone in some cameras (mostly low-end compacts and camera phones), resulting in ugly “halo” effects near edges. But it’s entirely beneficial when done properly. Almost every digital camera sharpens images to some degree. Some models […]

SFRreg INI file reference

For more information on how to use INI files in Imatest IT, we recommend the Imatest INI File Reference This document was created by running sfrreg in Imatest 5.2.0. ALPHA on 31-May-2019 14:48:43. For Imatest IT, most of these entries don’t need to be entered. Many don’t affect Imatest IT results: they control interactive figure displays or figure output formats (figures are often not used in Imatest IT). Background Meaning Yellow Yellow background: Important to Imatest IT. Parameter and Description are in boldface. [IT] Cyan Cyan background: Figure settings. (Figures are used infrequently for IT.) [f] Gray Gray background: For […]

Shannon information capacity

Photographic scientists and engineers stress the fact that no single number satisfactorily describes the ability of a photographic system to reproduce the small-scale attributes of the subject —Leslie Stroebel,John Compton, Ira Current, Richard Zakia Basic Photographic Materials and Processes, Second edition, p. 273 (Micro-image evaluation chapter), Focal Press, 2000 News: Imatest 2020.1 (March 2020)  Shannon information capacity is now calculated from images of the Siemens star, with much better accuracy than the old slanted-edge measurements, which have been deprecated and replaced with a new method (convenient, but less accurate than the Siemens Star). Siemens Star measurements are the recommended method […]

SFRplus INI file reference

For more information on how to use INI files in Imatest IT, we recommend the Imatest INI File Reference For Imatest IT, most of these entries don’t need to be entered. Many don’t affect Imatest IT results: they control interactive figure displays or figure output formats (figures are often not used in Imatest IT). Background Meaning Yellow Yellow background: Important to Imatest IT. Parameter and Description are in boldface. [IT] Cyan Cyan background: Figure settings. (Figures are used infrequently for IT.) [f] Gray Gray background: For interactive operation. No effect on IT. Clear Clear background: Results details (units, scaling, etc.) […]

SFRplus special topics: quadrants and saturation

These posts describe several topics, including: SFRplus Quadrant analysis (it includes the center region as well), Saturation analysis, which attempts to estimate the severity of saturation in slanted-edge regions (ROIs), and a few other recent additions (November 2012). Saturation is important because saturated light or dark regions will result in artificially high MTF readings. How to select regions at a fixed distance from center to corner (typically in the range of 65-85%)

SFRplus and eSFR ISO INI Reference

Since SFRplus (and eventually eSFR ISO, which uses almost all the same settings) is included in IT EXE and DLL, users may sometimes need to examine or edit the INI file used to control IT versions. Most of the settings in the [sfrplus] or [esfriso] section are set by one of the three SFRplus or eSFR ISO Settings windows that can be opened when SFRplus is run in Rescharts (or by clicking SFRplus setup in the Imatest main window). A few are set by responses to other windows or user actions. Settings that affect only Rescharts mode (and hence do […]

SFR results: Multiple ROI (Region of Interest) plot

Imatest SFR allows you to analyze and display several regions of interest (ROIs) in an image. Display options can be selected from three dropdown windows from the SFR settings window. Multi-ROI plots lets you choose the plot type: 1D or 2D; units in Cycles/Pxl, LW/PH (Line Widths per Picture Height), or LP/PH (Line Pairs per Picture Height).The 1D summary plots, which display results as a function of the distance from the image center, may be difficult to read for lenses that are poorly centered and hence have asymmetrical response. In most cases 2D summary plots are far more readable. 1D […]

SFR INI file reference

* indicates that this field will be described in more detail at the bottom of this document (Much of the text at the bottom will be common to several ini file reference pages). For more information on how to use INI files in Imatest IT, we recommend the Imatest INI File Reference For Imatest IT, most of these entries don’t need to be entered. Many don’t affect Imatest IT results: they control interactive figure displays or figure output formats (figures are often not used in Imatest IT). Background Meaning Yellow Yellow background: Important to Imatest IT. Parameter and Description are […]

Rescharts slanted-edge modules Part 4: Other results

Imatest Rescharts slanted-edge modules perform highly automated measurements of several key image quality factors using specially-designed test charts. The user never has to manually select Regions of Interest (ROIs). This page covers results that are (mostly) not derived from the slanted-edges themselves, including Noise (best in eSFR ISO) Distortion  (differing detail in different modules; best with SFRplus and eSFR ISO. Described in detail here. Tonal response*  (no noise statistics for SFRplus) Color accuracy*  when used with an SFRplus, eSFR ISO, or SFRreg center charts that contain a color pattern Vanishing resolution, aliasing, and Moiré from Wedge patterns in eSFR ISO ISO sensitivity*  (Saturation-based and […]

Rescharts Slanted-Edge Modules Part 3: Edge Results

Imatest Rescharts slanted-edge modules perform highly automated measurements of several key image quality factors using specially-designed test charts. The user does not need to manually select Regions of Interest (ROIs). This page covers results that are derived from the slanted-edges (i.e., not from grayscale, color, or wedge patterns). It also covers text output (CSV and JSON) files. Sharpness, expressed as Spatial Frequency Response (SFR), also known as the Modulation Transfer Function (MTF), can be displayed in several ways for individual edges or from the entire pattern, Lateral Chromatic Aberration Other results, not derived from slanted-edges are covered in Part 4. Noise (best […]

Raw Files

Introduction – Using raw files – Bayer raw and RCCC files – LibRaw demosaicing (for commercial raw files)  Bayer frequency units – DNG files – Rawview utility – Generalized Read Raw (for binary raw files)  Decompanding – Creating Synthetic raw images   The unprocessed digital output of an image sensor is called RAW image data. In this document, we sometimes refer to raw files from commercial cameras or development systems as Camera raw to distinguish them from Bayer raw files, which are standard monochrome image files that contain undemosaiced (Bayer) data. Imatest modules can analyze raw files directly or after demosaicing. Bayer […]

Pre-distorted and special charts for Fisheye Lenses

Automatic region detection in SFRplus and eSFR ISO tolerates moderate amounts of optical distortion (pincushion or barrel), but it has definite limits. In this page we describe special versions of SFRplus and eSFR ISO charts that can work (i.e., can be detected automatically) with highly barrel-distorted (“fisheye“) lenses, with fields of view up to around 160 degrees— which are used in a number of applications, particularly for automotive rear-view and sports cameras. Cameras with fields of view over 160 degrees— even approaching 360 degrees— can be tested with the SFRreg module, which uses multiple individual “registration mark” charts facing the […]

Nyquist frequency, Aliasing, and Color Moire

Although sharpness is an important image quality factor, a sharper lens is not always better. A lens can be too sharp for a sensor, resulting in disturbing visual artifacts. These artifacts, which include “stair-stepping” and moiré patterns (low frequency patterns that can be strongly colored), can appear because digital cameras— and all digitally sampled systems— have a maximum spatial frequency, called the Nyquist frequency, beyond which scene information cannot be correctly reproduced. Any information above the Nyquist frequency that reaches the sensor will be “aliased” to a lower spatial frequency, which can result in the artifacts described below. Sampling – Nyquist […]

Nonuniformity Correction in grayscale and color chart modules

Imatest can correct for nonuniform illumination and lens response (vignetting) in Imatest modules that analyze grayscale and/or color charts, including Color/Tone Setup (formerly Color/Tone Interactive), Color/Tone Auto (formerly Color/Tone Auto), Colorcheck, and Stepchart. Nonuniformity correction involves reading and specifying a second image, taken from a flat-field target (plain gray or white) under identical conditions to the test image.  Note that the correction described in this page is not the same as nonuniformity correction for slanted-edge MTF measurements. Not also that Color/Tone Interactive (a highly interactive module) and Color/Tone Auto (a batch-capable fixed version of Color/Tone Interactive) are recommended for new […]

Managing Supply Chain Image Quality with Imatest

Published January 30 2015 By Henry Koren, with contributions by Norman Koren. Edited by Matthew Donato, Jackson Roland and Ty Cumby. Table of Contents 1. Introduction The quality of imaging systems in mobile devices plays an increasingly important role in consumer purchasing decisions. A mobile device that fails to deliver acceptable quality images can have an adverse effect on the consumer’s brand loyalty, whether or not the customer has returned it. Unless proper care is taken, raising camera quality standards can reduce manufacturing yield. This could damage a supplier’s profitability as well as endanger their ability to deliver the required […]

Main Window (classic mode)

The Imatest Classic main window is the heart of Imatest Master: it’s where you open the analysis and utility modules. It’s complex but powerful. It consists of several well-populated dropdown menus, two columns of buttons (fixed and interactive analysis modules), and a tabbed area where you can select Utility, Data, and Help tabs. Imatest main window The contents of the three tabs on the right, Utility, Data, and Help , are shown in the right three columns of the table below, which has a similar structure as the Imatest main window. Map of Imatest main window, with links to instructions […]